SMART FLASH AI-700X
SMART FLASH AI-700X
 Carry out the separations of samples ranging from a few milligrams to dozens of grams automatically Assure good sample separations due to the integration of TLC image reader and Smart Flash One and only flash system that can develop the optimized method based on the true theory of flash chromatography Integration of TLC Image Reader and Flash Chromatography System Capture TLC image and show it on monitor screen The Smart Flash AKROS integrated with TLC reader is an indispensable tool to be used by synthetic organic and natural products chemists to quickly and efficiently purify samples ranging from a few milligrams to dozens of grams. “AKROS mode” is designed based on Yamazen’s proprietary EPC (Elution Position Control) theory which is an advancement of the familiar theory of column chromatography. It calculates the sample’s elution position and the maximum sample loading amount for each column selected and coupled with a highly sensitive UV detector, elutes the target compound always at the most efficient position, assuring a high resolution in sample purification. AKROS captures a TLC image and shows it on the display screen along with the chromatograph’s sample peaks, which enables the cross-referencing of sample spots on TLC to sample peaks. AKROS, the “TLC Flash Chromatography System” helps the chemist to identify the target peak by cross-referencing TLC pattern to sample peaks and by comparing the intensity of sample peaks to the darkness or lightness of TLC spots. Moreover, it makes the result file of a sample run more useful as method data since the TLC image is copied and attached to the file.



TECHNICAL SPESIFICATION
Controller Laptop or Desktop
Application software Eluting position controllable “Rf Gradient” Method
● 4-column volume elution of the target compound minimizes solvent use and waste disposal. Cost is drastically saved and It’s Eco-friendly!
● Changes method parameters on the fly.
● Scale up – Transfer method from one size column to another.
Slow gradient to apply for high polar solvents Ultra-slow gradient (0-3% over 30 minutes) is possible.
Pumping system, Model No.580S 0-80ml/min, 1.0Mpa (145psi)
Fixed wavelength UV detector, Model prepUV-254 254nm, 0.08-5.12 AUFS
Variable wavelength UV detector, Model prepUV-10VH 200-400nm, 0.02-10.24 AUFS
Variable 2-wavelength UV detector, Model prepUV-20VH 200-400nm, 0.02-10.24 AUFS
Variable wavelength UV-VIS detector, Model prepUV/VIS-10VH 200-800nm, 0.02-10.24 AUFS
Variable 2-wavelength UV-VIS detector, Model prepUV/VIS-20VH 200-800nm, 0.02-10.24 AUFS
Fraction collector, Model FR-360 A pair of the rack, X-Y driven, fraction modes of Time, Peak, Peak & Valley & Manual Collect
TLC Image Reader One each of UV lamp and visible lamp Streamlined from a TLC scanning to a sample run
Floor space (W x D x H) H = height of column stand 50 x 45 x 78cm (19.7x 17.7 x 30.7 inch)
Certifications JIS and CE
Options Solvent & waste level monitor, Column air purge
 