LC 9110G-9130G
LC 9110G-9130G
 
  •  
  •  UV Detector
As preparative dedicated detector, it has developed its stability and sensitivity can detect most organic compounds.

  UV-254 Next UV-370 Next UV-600 Next UV-VIS 4ch Next
Detection Fixed wavelength Variable wavelength Variable wavelength 4channel variable wavelenghth
Wave length 254nm 195~370nm 195~600nm 190~480nm
Measurement Method Single beam Double beam single beam
Flow Cell Cell Length:0.3mm,
Cell volume:40µl
(option:1.0mm,2.4mm)
Cell Lenght:0.5mm,
CEll volume:20µl
(Option:0.2mm, 0.1mm)
CEll Lenght:0.3mm,
CEll volume:40µl
(Option:1.0mm, 2.4mm)



RI Detector
 
 
 Stable baseline can be obtained quickly. Applicable for both prepative and analytical HPLC.


 
 
 
  RI-700 Next
Measurement Method Deflection
Flow Cell 8µl volume
RI Range 1.00-1.75
Attenuator 1-2000 in 12 steps

Chromatogram Data Acquisition System


There are a few selection of software depends on your need and detector selection. UV-Vis 4ch Next works perfectly with JAI Scan and UV-Vis 4ch NEXT works perfectly with JAI Scan and UV-VIS DAD NEXT works with Clarity TM. For other detectors, please choose from Prepure or JDS series.

Specifications


  LC-9110G Next LC-9130G Next
Pump Model P-9101B P-9140B
Pump Type REciprocating double plunger
Flow Rate 0.001-10.00ml/min 0.001-30.00ml/min
Maximum Dischange Pressure 30MPa(0.01-5.00ml/min)
25MPa(5.01-10.00ml/min)
20MPa(0.01-15.00ml/min)
15MPa(15.01-25.00ml/min)
10MPa(25.01-30.00ml/min)
Plunger Ø4.0mm Ø4.0mm
Stroke 8mm
Dischange rate per stroke 100µl 300µl
Flow Stability CV less than 0.3
Operation Panel  8.4inch lcd touch-sensitive screen
ISO/GRA Mode Switching Program and display on LCD touch-sensitive screen
Gradient method Low-pressure mixture method
Gradient solvent 4solvents
Pressure Display& Limiterr Program and display on LCD touch-sensitive screen
Variable Injector (Manual) Rheodyne 7725i
Sample Loop 3ml (standard)
5ml,10ml(optional)
10ml(standard)
5ml,15ml(optional)
Event Marker Injection,Recycle and Collect
Recycle System* With non-diffusion function recycling system(patent)
Recycle Method* Swiching scheme of solenoid valve
Auto Recycler* Built-in (1to99 times repetition possible) 
Repeat Injector* Direct auto sample loading system (100µl to99.9ml) 
Manual Recycle Program and display on LCD
Fraction Collector  Standard accessary. Max 33 fraction (manual/time mode) 
Auto Rerun Function  Save previous operation and rerun up to 99 times. 
Injection overlap Function Time saving auto injector 
Auto Cleanup Function Flow channel washing by program 
Dimensions of Mainframe(mm) 464(W)x492(H)x504(D) 
Tray dimensions for fraction collector 440(W)x325(D) 
Solvent rack demensions for Ø40mm columns(s) 240(W)x650(H)x470(D) 
Power Supply 85V-240V Power consumption 800VA 
Weight  Approx. 40kg 